www.telecom.fr

 
MATERIELS OPERATEURS TELECOM ET INSTALLATEURS : FIBRE OPTIQUE - TELECOM ET RESEAUX - MOTOROLA - PABX - ELECTRICTE HT....


MULHOUSE FRANCE
 

 
 
CABLE OPTIQUE

AERIEN

 


SLT-SA-SJ-A (A-DQ(ZN)(SR)2YT)
SLT-NMA-SJ-A
MLT-NMA-SJ–A (A-DF2YT)
MLT-SA-SJ –A (A-DF(SR)2YT)
MLT-SA-DJ –A (A-DF2Y(SR)2YT)
MLT-NMA-DJ–ADSS(A-DF(ZN)2YB2Y)
A-V2H(SR)T2Y nx1
 

 

SYMBOLS DESCRIPTION

SLT

SINGLE LOOSE TUBE

MLT

MULTI LOOSE TUBES CABLE

SA

CORRUGATED STEEL TAPE

NMA

NON METALLIC STRENGHT MEMBER

DA

DOUBLE ARMOR - TWO LEYERS OF GALVANIZED STEEL TAPE

SJ

SINGLE JACKET

DJ

DOUBLE JACKET

-A

AERIAL CABLE

-P

FIBER OPTIC + POWER HYBRID CABLE

LSZH

LOW SMOKE ZERO HALOGEN SHEATH

ADSS

ALL DIELECTRIC SELF SUPPORTIGN CABLE

-T.T.

TURKISH TELECOM STANDARTS

DIN VDE 0888

OPTICAL FIBER CABLES STANDART

A-

OUTDOOR CABLE

B

ARMORING

(BN)

GLASS-YARN - NON METALIC ARMORING FOR RODENT PROTECTION

D

LOOSE BUFFER TUBE, FILLED

E

SINGLE MODE FIBER

F

FILLING COMPOUND IN THE CABLE CORE

G

MULTI MODE FIBER

J-

INDOOR CABLE

(L)

LAMINATED ALUMINUM SHEATH

Q

(DRY SWELLABLE METARIAL IN THE CABLE CORE (DRY CORE)

(SR)

ARMORING BY LAMINATED, CORRUGATED, LONGITUDINAL, OVERLAPPED STEEL TAPE

Y

POLYVINYL CHLORIDE FACKET

2Y

POLYETHYLENE JACKET

(ZN)

NON-METALIC ANTI-BUCKLING ANG STRENGHT MEMBER

 

CABLE TYPE : SLT-SA-SJ-A (A-DQ(ZN)(SR)2YT)
APPLICATION : - Light weight structure enables easy and fast installation
- Small diameter permits easy handling
- Rodent proof and waterproof
- Preferred for LAN, WAN, MAN applications for structural cabling and premise networks
- Aerial applications between the poles under light weather conditions
CONSTRUCTION : 1.Outer PE Sheath ( Optional LSZH sheath )
2.Corrugated Steel Tape Armored .
3.Non metallic strength member Glass Yarn
4.PBT Tube
5.Water Resistive Tube filling Compound
6.Optical fibers
7.Ripcord
8.Supporting Steel Wire
9.Web

Optik Fiber Type SM : 652-B, G 652-D, G 655 - MM : 62.5/125 OM1, 50/125 OM2, 50/125 OM3
Core Count 2 to 12
Cable Weight (kg/km) 135
Outer Diameter (mm) 7.5x14.5
Max. Pole Span 60 m
Tensile Strength (N) (IEC 794-1-E1) 2000
Crush Strength (N/10 cm) (IEC 794-1-E3) 2500
Min. Permissible Bending Radius (mm) (IEC 794-1-E 11) 15xo static &20xo dynamic whereo is cable outside diameter in mm
Temperature Range (°C) (IEC 794-1-F -1)

 

Operation -40 to + 70 Installation -30 to + 60

CABLE TYPE : SLT-NMA-SJ-A
APPLICATION : - Light weight structure enables easy and fast installation
- Small diameter permits easy handling
- Rodent proof and waterproof
- Preferred for LAN, WAN applications for structural cabling and premise networks
- Aerial applications between the poles under light weather conditions
CONSTRUCTION : 1.Outer PE Sheath ( Optional LSZH sheath)
2.Non metallic Strength Member Glass Yarn
3.Tube
4.Water Resistive TubeFfilling Compound
5.Optical Fibers
6.Ripcord
7.Galvanized Steel Wire
8.Web

Optik Fiber Type SM : 652-B, G 652-D, G 655 MM : 62.5/125 OM1, 50/125 OM2, 50/125 OM3
Core Count 2 to 12
Cable Weight (kg/km) 135
Outer Diameter (mm) 7x12
Max. Pole Span 45 m
Tensile Strength (N) (IEC 794-1-E1) 1600
Crush Strength (N/10 cm) (IEC 794-1-E3) 1500
Min. Permissible Bending Radius (mm) (IEC 794-1-E 11) 15xo static &20xo dynamic where o is cable outside diameter in mm
Temperature Range (°C) (IEC 794-1-F -1)

 

Operation -30 to + 60 Installation -20 to + 50

 

CABLE TYPE : MLT-NMA-SJ–A (A-DF2YT)
APPLICATION : -For Aerial Cable installation between poles
-Resistance to tough weather conditions
-Suitable to be used up to 50 meters pole span
-Black polyethylene sheath supplies protection against UV Ray
-Light construction enables easy installation and quick handling
-Preferred for telecom networks for backbone cabling
CONSTRUCTION : 1.Outer Black PE Sheath.
2.Core Wrapping(s)
3.PBT Tube
4.Core filling Compound..
5.Optical fiber
6.Water Resistive Tube filling Compound
7.Non Metallic Central Strength Member
8.Supporting Steel Wire
9.Ripcord
10.Web

 
Optik Fiber Type SM : 652-B, G 652-D, G 655 MM : 62.5/125 OM1, 50/125 OM2, 50/125 OM3
Tensile Strength (N) (IEC 794-1-E1) 3000 to 5000
Crush Strength (N/10 cm) (IEC 794-1-E3) 3000
Min. Permissible Bending Radius (mm) (IEC 794-1-E 11) 15xo static &20xo dynamic where o is cable outside diameter in mm
Temperature Range (°C) (IEC 794-1-F -1)

 

Operation -40 to + 70 Installation -30 to + 60
Fiber Count Buffer Count Filler Count Messenger Wire Overall Diameter Cable Weight (Kg/Km)

4

1

5

7*1,1

11X20

200

6

1

5

7*1,1

11X20

200

8

4

4

7*1,1

11X20

200

10

5

1

7*1,1

11X20

200

12

3

3

7*1,1

11X20

200

16

2

2

7*1,1

11X20

200

20

5

1

7*1,1

11X20

200

24

6

-

7*1,1

11X20

200

36

6

-

7*1,1

11X20

200

48

6

-

7*1,1

11X20

200

CABLE TYPE : MLT-SA-SJ –A (A-DF(SR)2YT)
APPLICATION : -For Aerial Cable installation between poles.
-Resistance to tough weather conditions
-Suitable to be used up to 50 meters pole span
-Corrugated Steel Armor provides protection against Rodents and moisture.
-Black polyethylene sheath supplies protection against UV Ray.
-Light construction enables easy installation and quick handling
-Preferred for telecom networks backbone cabling.
CONSTRUCTION : 1.Outer Black PE Sheath.
2.Corrugated Steel Tape armored..
3.Core Wrapping(s)
4.PBT Tube
5.Core filling Compound.
6.Optical fiber
7.Water Resistive Tube filling Compound
8.Non Metallic Central Strength Member(FRP)
9.Supporting Steel Wire
10.Ripcord
11.Web

 
Optik Fiber Type SM : 652-B, G 652-D, G 655 MM : 62.5/125 OM1, 50/125 OM2, 50/125 OM3
Tensile Strength (N) (IEC 794-1-E1) 3000 to 5000
Crush Strength (N/10 cm) (IEC 794-1-E3)

 

4000
Min. Permissible Bending Radius (mm) (IEC 794-1-E 11) 15xo static &20xo dynamic where o is cable outside diameter in mm
Temperature Range (°C) (IEC 794-1-F -1)

 

Operation -40 to + 70 Installation -30 to + 60

 

Fiber Count Buffer Count Filler Count Messenger Wire Overall Diameter (mm) Cable Weight (Kg/Km)

4

1

5

7*1,3

12X22

290

6

1

5

7*1,3

12X22

290

8

4

4

7*1,3

12X22

290

10

5

1

7*1,3

12X22

290

12

3

3

7*1,3

12X22

290

16

2

2

7*1,3

12X22

290

20

5

1

7*1,3

12X22

290

24

6

-

7*1,3

12X22

290

36

6

-

7*1,3

12X22

290

48

6

-

7*1,3

12X22

290

 

CABLE TYPE : MLT-SA-DJ –A (A-DF2Y(SR)2YT)
APPLICATION : -For Aerial Cable installation between poles.
-Resistance to tough weather conditions
-Suitable to be used up to 50 meters pole span
-Corrugated Steel Armor and Second Jacket provides extra protection against Rodents, moisture and all external effects.
-Black polyethylene sheath supplies protection against UV Ray.
-Preferred for telecom networks backbone cabling.
CONSTRUCTION : 1.Outer Black PE Sheath.
2.Corrugated Steel Tape armored.
3.Inner Black PE Sheath.
4.Core Wrapping(s)
5.PBT Tube
6.Core filling Compound.
7.Optical fiber
8.Water Resistive Tube filling Compound
9.Non Metallic Central Strength Member(FRP)
10.Supporting Steel Wire
11.Ripcord
12.Web

 
Optik Fiber Type SM : 652-B, G 652-D, G 655 MM : 62.5/125 OM1, 50/125 OM2, 50/125 OM3
Tensile Strength (N) (IEC 794-1-E1) 3000 to 5000
Crush Strength (N/10 cm) (IEC 794-1-E3)

 

5000
Min. Permissible Bending Radius (mm) (IEC 794-1-E 11) 15xo static &20xo dynamic where o is cable outside diameter in mm
Temperature Range (°C) (IEC 794-1-F -1)

 

Operation -40 to + 70 Installation -30 to + 60
Fiber Count Buffer Count Filler Count Messenger Wire Overall Diameter (mm) Cable Weight (Kg/Km)

4

1

5

7*1,5

16X26

350

6

1

5

7*1,5

16X26

350

8

4

4

7*1,5

16X26

350

10

5

1

7*1,5

16X26

350

12

3

3

7*1,5

16X26

350

16

2

2

7*1,5

16X26

350

20

5

1

7*1,5

16X26

350

24

6

-

7*1,5

16X26

350

36

6

-

7*1,5

16X26

350

48

6

-

7*1,5

16X26

350


 

CABLE TYPE : MLT-NMA-DJ–ADSS(A-DF(ZN)2YB2Y)
APPLICATION : - Aerial Cable type without Steel Messenger Wire
-Aerial installation between the poles with the help of special installation /suspension equipment.
-All dielectric construction enables application in power lines side by side with Energy Cables
-Very Light and easy to install
- Special High Density Black PE provides excellent resistance during installation and protection against external effects like tough weather conditions and UV Ray during operation.
- Generally preferred as Aerial backbone cable for Wide Area Telecom Networks
CONSTRUCTION : 1.Outer Black special HDPE Sheath.
2.High modulus Aramid Yarns
3.Optional Inner PE Sheath.
4.Core Wrapping(s)
5.PBT tube
6.Core filling Compound.
7.Optical fibers
8.Water Resistive Tube filling Compound
9.Non Metallic Central Strength Member
10.Ripcord

 

Optik Fiber Type SM : 652-B, G 652-D, G 655 MM : 62.5/125 OM1, 50/125 OM2, 50/125 OM3
Tensile Strength (N) (IEC 794-1-E1) 2700 (Min.) to 15000
Crush Strength (N/10 cm) (IEC 794-1-E3)

 

4000
Min. Permissible Bending Radius (mm) (IEC 794-1-E 11) 15xo static &20xo dynamic where o is cable outside diameter in mm
Temperature Range (°C) (IEC 794-1-F -1)

 

Operation -40 to + 70 Installation -30 to + 60

 

Fiber Count

Buffer Count Filler Count Inner and outer sheath thickness Cable Diameter Aprx Cable Weight (Kg/Km)

4

1

5

1.1/1.6

14

140

6

1

5

1.1/1.6

14

140

8

2

4

1.1/1.6

14

140

12

1(3)

5 (3)

1.1/1.6

16

150

24

2

4

1.1/1.6

16

150

36

3

3

1.1/1.6

16

150

48

4

2

1.1/1.6

16

160

60

5

1

1.1/1.6

16

180

72

6

-

1.1/1.6

16

180

Sag and Tension Parameter

Installation Parameter Span (m) Sag % Tension N LIGHT Sag % Tension N MEDIUM Sag % Tension N HEAVY Sag % Tension N

30

1.0

445

1.2

1000

2.3

1300

3.0

1960

45

1.0

665

1.3

1390

2.5

1780

3.3.3.6

2640

60

1.0

880

1.4

1740

2.7

2230

3.9

3265

75

1.0

1110

1.4

2100

2.8

2650

4.1

3815

90

1.0

1130

1.5

2400

3.0

3030

-

4345

110

1.0

1570

1.5

2720

3.1

3400

-

-

120

1.0

1790

1.6

3050

3.2

3785

-

-

140

1.0

2050

1.6

3350

3.3

4125

-

-

150

1.0

2230

1.6

3650

3.3

4455

-

-

170

1.0

2500

1.7

3950

-

-

-

-

180

1.0

2700

1.7

4250

-

-

-

-

CABLE TYPE : A-V2H(SR)T2Y nx1
APPLICATION : Outdoor and Aerial installations; Ready for direct connectorization in field; Suitable for backbone and horizontal sub systems such as FTTH and FTTD
CONSTRUCTION : 1.Optical fiber
2.Tight buffered fibre of 900 m diameter (Easy to strip)
3.Non-metallic strenght members (Aramide or glass yarn)
4.Flame Retardant Non-Corrosive / Low Smoke Zero Halogen Inner Jacket
5.Corrugated Steel Tape armored
6.Outer Black PE Sheath
7.Supporting Steel Wire
     

Number of Fibers (n) 2 – 12
Optic Fiber Type ITU-T G.651 (MM), ITU-T G.652 (SM), ITU-T G.655 & G.656 (NZDS Fiber)
Outer Diameter (mm) 8.5X16 [mm] to 13.0X21 [mm]
Weight (kg/km) 150, 190
Tensile Strength (N) 2000
Crush Resistance (N) 2000
Minimum Bending Radius (mm) 20 x D ( Where D, overall diameter of cable)
Operating Temperature (°C) -30°C to +70°C
Standard Cable Color Black (Other colors are available upon request)
Standard Reel Length 1000-2000 m
Standard Cable Marking SIPTEL Cable

 

© 2011 SIPTEL™ Tous droits réservés

Accueil - Groupe - Mentions légales - Confidentialité - Recrutement - Références - Contact